This important configuration parameter relates to TCP protocol communication in MTX-Tunnel. They are mandatory when using 2G/3G/4G TCP – Serial RS232/485 tunnel in client (MTX_mode: client) or server mode (MTX_mode: server)
Table of Contents
TCP_IP
Description: IP server address that MTX-Tunnel will connect to if it is client configured (MTX_mode: client).
Possible values:
- IP address format XXX.XXX.XXX.XXX or DNS
- Default value: none
Additional notes:
- This parameter is also used if MTX-Tunnel is configured in server mode (MTX_mode: server) and if MTX_temporalClient is enabled (value =”on”). The IP address or DNS name is used by the temporal client to establish a connection. Please read the information regarding the MTX_temporalClient parameter for more details
TCP_port
Description: TCP port value: MTX-Tunnel is used in both client (MTX_mode: client) and server mode (MTX_mode: server). In server mode, MTX-Tunnel waits for incoming connections at the specified port. This specifies the TCP port that MTX-Tunnel will connect to when it is configured in client mode (MTX_mode: client), and in server mode (MTX_mode: server) it indicates the TCP port where incoming connections are made.
Possible values:
- 1… 65535
- Default value: 20010
Additional notes:
- This parameter is also used if MTX-Tunnel is configured in server mode and MTX_temporalClient parameter is enabled (value =”on”). The IP address or DNS name is used by the temporal client to establish a connection. Please read the information regarding the MTX_temporalClient parameter for more details
TCP_IP2
Description: This parameter has only been available since the MTX-Tunnelv7.8. In the event that the modem is configured as a client (MTX_mode: client) and the connection is permanent (GPRS_timeout: 0), you can specify an IP address in this parameter which allows you to establish a second 2G/3G/4Gserial gateway. This means that on one hand you have the first 2G/3G/4G-serial gateway associated with the modem’s COM1 port and on the other hand you have the new gateway associated with the modem’s COM2 port.
Possible values:
- An IP address XXX.XXX.XXX.XXX or a DNS
- Default Value: none
Additional notes:
- This parameter can only be used with modems that have two serial ports.
TCP_port2
Description: This parameter has only been available since MTX-Tunnelv7.8. In the event that the modem is configured in client mode (MTX_mode: client), the connection is permanent (GPRS_timeout: 0) and you have specified an IP address in the parameter TCP_IP2, this parameter allows you to choose the port for the TCP connection.
This means that on the one hand you have the first 2G/3G/4G-serial gateway associated with the modem’s COM1 port and on the other hand you have the new gateway associated with the modem’s COM2 port.
From MTX-Tunnel v9 onwards, in case the modem is configured in Server mode (MTX_mode: server) and the connection is permanent (GPRS_timeout: 0) , this parameter allows you to specify the TCP listening port of the second gateway.
That means that on the one hand you have a 2G/3G/4G-serial gateway associated with the modem’s COM1 port, and on the other hand you have the new gateway associated with the modem’s COM2 serial port. So, two serial gateway running in parallel.
Possible values:
- 1… 65535
- Default Value: 20010
Additional notes:
- This parameter can only be used with modems that have two serial ports.
Les accès par défaut sont :
Saisir le mode de connexion « Ethernet » ou « modem » :
Dans le cas d’une configuration par Ethernet, veiller à ce que les paramètres IP soient compatibles avec l’accès au serveur d’après la configuration du réseau local du concentrateur. Dans le cas d’une connexion par Ethernet, la configuration doit être compatible avec la topologie du réseau local du concentrateur afin qu’il puisse accéder aux serveurs. Cette configuration se fait via la page de configuration « Networks » (voir chapitre 3.2.2.3 : « Réseaux (Networks) »).
Dans le cas d’une connexion par modem, la configuration du modem doit être correcte avant de pouvoir effectuer une connexion. Cette configuration se fait dans la page de configuration « Modem » (voir chapitre 3.2.2.4 : « Modem »).
Les paramètres des serveurs à configurer au minimum sont les suivants :
Il faut donc configurer les champs : « Interface », « Type », « Server type », « Address », « Port », « Login » et « Password ».
Les autres champs peuvent être laissés aux valeurs par défaut à condition que les répertoires aient été créés correctement auparavant. Voir chapitre 3.1.2 : « Fichiers de configuration » pour plus de détails.


Attendre. Le concentrateur va redémarrer avec sa configuration usine.