Suchen Sie etwas anderes?
The “ULP_” configuration parameter is only related to MTX-Tunnel installed on the modem terminal modem. ULP means Ultra Low Power mode in which power consumption is only 10uA. In this mode, the modem remains on standby waiting for a configured alarm or a change in the level of digital input. Then all 2G/3G/4G tunnels and services are established and after a different configured time, it will switch off and return to ULP mode.
If your application needs low power consumption please read the following configuration parameters:
Table of Contents
ULP_enabled
Description: This parameter allows to activate the ULP service (low power) in case the MTX model has it.
Possible values:
- on, off
- Default value: off
Additional notes:
- In SMS mode (ULP_mode: sms) you must use the “ULP_sleepMode:minutes” configuration parameter.
- It is not possible to set a time for the modem to wake up from the ULP mode; it is only possible to specify a time for it to sleep. This is because “ULP_sleepMode: date” needs a GPRS connection for time synchronization and it can only connect during normal wakeup mode.
- Check Annexes for more information. Contact iotsupport@mtxm2m.com for more help
- Check also parameters ALARM_ulpEnabled and ALARM_ulpMessage
ULP_sleepMode
Description:
ULP sleep mode:
- “minutes” configuration value: MTXTunnel wakes up and connects to 2G/3G/4G enabling services (Serial tunnel, WebServer, Telnet…). MTX-Tunnel will remain active the time specified in ULP_secondsOn. Passed that time, MTX-Tunnel will go into ULP mode (~10uA), waking up again after X minutes specified in the parameter ULP_minutesOff.
- “date” configuration value: MTXTunnel wakes up and connects to 2G/3G/4G enabling services (Serial tunnel, WebServer, Telnet…). MTX-Tunnel will remain active the time specified in ULP_secondsOn. Passed that time, MTX-Tunnel will go into ULP mode (~10uA), waking up again at the time specified in the parameters ULP_time1, ULP_time2, … ULP_time10.
Possible values:
- minutes, date
- Default value: minutes
Additional notes:
- If you are going to use date mode you MUST synchronize the internal timing with the server timing using the MTX_TPServer parameter. The modem will connect with the server’s time and update its internal timing every time it wakes up. MTX-Tunnel uses UTC timing
ULP_minutesOff
Description: this parameter specifies the number of minutes during which the modem is in ULP (Ultra Low Power). After this time, the modem switches to normal mode.
Possible values:
- 0… 43200
- Default value: 0
Additional notes:
- Once the modem wakes up, it will remain on the time specified in ULP_secondsOn
- If you select a value ULP_minutesOff=0 and the parameter ULP_sleepMode has the value “minutes,” the modem will only awake with a tamper input (digital input)
ULP_secondsOn
Description: this parameter specifies the number of seconds during which the modem is in ULP (Ultra Low Power). After this time, the modem will go back to sleep.
Possible values:
- 0… 86400
- Default value: 60
Additional notes:
- Once the modem goes to sleep, it will remain that way the time specified in ULP_minutesOff
ULP_time1, ULP_time2… ULP_time10
Description: up to 10 different specified alarm times to wake up MTX-Tunnel from ULP mode (2uA) and activate a GPRS session. The GPRS session will be active during GPRS_timeout second time value.
Possible values:
- DDHHMM (DD: day, HH hour in 24h format & MM (minutes)
- Default value: none
Additional notes:
- DD and HH values can be XX, meaning any value
- Examples:
- ULP_time1: 012200
MTXTunnel wakes up (changes from ULP to normal mode) every 1st day of the month at 22:00) - ULP_time1: 011030
ULP_time2: 151030
MTX-Tunnel wakes up every 1st and 15th day of the month, at 10:30 - ULP_time1: XX1800
MTXTunnel wakes up every 1st day of the month, at 18:00 - ULP_time1: XX0200
ULP_time2: XX1400
MTXTunnel wakes up from ULP to normal mode every day of the month, at 02.00 and 14.00 - ULP_time1: XXXX00
MTXTunnel wakes up from ULP mode, every day of the current month and every hour - Modem time uses UTC HOUR. Check differences with local time
ULP_smsExtended
Description: If disabled (value “off”) and the ULP mode is SMS (ULP_mode: sms), an SMS will be sent with the text specified in the MTX_IDClient parameter. If enabled (value “on”), the SMS will also contain extended telemetry as specified in the ULP_mode parameter.
Possible values:
- on, off
- Default value: on
Additional notes:
- Sometimes you just need to send the “MTX_IDClient” value parameter and not the GPIOs values as this saves power
- For example when the digital tamper input changes, the SMS text will not include any value, just the “Input change”
ULP_smsNumber1, ULP_smsNumber2, ULP_smsNumber3
Description: This parameter sets the telephone numbers to which SMSs containing the GPIO and ADC values will be sent when ULP mode is SMS: (ULP_mode: SMS). You can use up to 3 phone numbers.
Possible values:
- National or international phone numbers are valid
- Default value: none
ULP_rtc
Description: This parameter configures the way to wake up the MTX-65-ULP modem.
Timing alarm: MTX-Tunnel wakes up when alarm timing occurs. Internal RTC is used.
Interruption digital input (tamper): MTX-65-ULP modem wakes up when a special digital trigger input is
activated.
Possible values:
- on, off
- Default value: on
Additional notes:
- Using MTX-65-ULP with the RTC disabled leaves only the digital input wakeup trigger which is the lowest power mode on MTX-Tunnel
Les accès par défaut sont :
Saisir le mode de connexion « Ethernet » ou « modem » :
Dans le cas d’une configuration par Ethernet, veiller à ce que les paramètres IP soient compatibles avec l’accès au serveur d’après la configuration du réseau local du concentrateur. Dans le cas d’une connexion par Ethernet, la configuration doit être compatible avec la topologie du réseau local du concentrateur afin qu’il puisse accéder aux serveurs. Cette configuration se fait via la page de configuration « Networks » (voir chapitre 3.2.2.3 : « Réseaux (Networks) »).
Dans le cas d’une connexion par modem, la configuration du modem doit être correcte avant de pouvoir effectuer une connexion. Cette configuration se fait dans la page de configuration « Modem » (voir chapitre 3.2.2.4 : « Modem »).
Les paramètres des serveurs à configurer au minimum sont les suivants :
Il faut donc configurer les champs : « Interface », « Type », « Server type », « Address », « Port », « Login » et « Password ».
Les autres champs peuvent être laissés aux valeurs par défaut à condition que les répertoires aient été créés correctement auparavant. Voir chapitre 3.1.2 : « Fichiers de configuration » pour plus de détails.


Attendre. Le concentrateur va redémarrer avec sa configuration usine.