Details of the example scenario:
- We need to be able to remotely access, via GPRS, an IP camera that is located in a solar farm to monitor neglected equipment
- The camera has an IP address of 192.168.1.70 and the webserver to which we need to connect is located in the TCP port 8080
- To economize, a SIM card with a dynamic public IP address will be used. We must be able to obtain the router’s IP address via a missed call from either of the following numbers: 666123456 and 666123457
- The router must be configured to detected possible GSM inhibitors. When a possible detection is made, a relay connected to a siren must be activated and, if the inhibitor signal is weak given it is not too close, an SMS alert must be sent and a GSM call made to the number 666123456
- The router should supervise a gate and if opened, an SMS alert must be sent to the numbers 666123456 and 666123457
- We will also use the router to take daily readings of an RS485 electricity meter (configuration 9600bps, 8N1) via a transparent GPRS/RS485 gateway
Solution: MTX-Router-Titan mini










Enter the “ethernet” or “modem” connection type:
For an ethernet configuration, make sure the IP parameters are compatible with server access according to the concentrator local network configuration. For an ethernet connection, the configuration must be compatible with the concentrator’s local network topology so that it can access the servers. This configuration is done from the “Networks” configuration page (see section 3.2.2.3: “Networks”).
For a modem connection, the modem configuration must be correct before a connection can be set up. This configuration is done from the “Modem” configuration page (see section 3.2.2.4: “Modem”).
The parameters for the servers to be configured are at least the following:
Therefore the following fields need to be configured: “Interface”, “Type”, “Server type”, “Address”, “Port”, “Login” and “Password”.
The other fields can be left at the default values subject to the directories having been properly created beforehand. See section 3.1.2: “Configuration files” for more details.

Wait. The concentrator will reboot using its factory configuration.