Tunnel – DynDNS configuration parameter: “DYNDNS_”
MTXTunnel version 5.0 and above include the “DYNDNS_” parameter. They refer to the DynDNS service which allows you to assign a DNS name to a dynamic IP address, in such a way that a DNS with the format “mymodem.dyndns.org” will always take note of the IP address obtained by the network operator at all times. MTXTunnel connects with […]
Tunnel – SMS Configuration parameter: “SMS_”
MTXTunnel has a lot of SMS features. SMSs can be used (sent and received) to configure, report, start/stop any service, etc. You need to configure the SMS messaging feature with the following parameters: SMS_sendIP Description: MTXTunnel starts the 4G/3G/2G connection and associated services (tunnel, WebServer, telnet …) if it receives a missed call or an […]
Tunnel – FIREWALL configuration parameters: “FIREWALL_”
MTXTunnel by default allows access from any IP address. If you enable a firewall, your system will be secure as you will avoid unauthorized access. This way, only configured IP (or DNS) addresses can connect and access MTX-Tunnel and the other services (GPRS serial tunnel, WebServer, Telnet…). FIREWALL_enabled Description: Parameter to enable firewall and to enable […]
Tunnel – ALARM Configuration parameter: “ALARM_”
MTXTunnel can send SMSs when the level of any digital input changes. This can be performed with the GPRS tunnel activated at same time. ALARM_gpioEnabled Description: This parameter will activate this SMS alarm feature when the digital input level changes. Possible values: on, off Default value: off Additional notes: Each platform type has its own specific input […]
Tunnel – UDP configuration parameter: “UDP_”
These parameters are related to MTX-Tunnel data communication using the UDP protocol. It is needed in the GPRS (UDP) – Serial (RS232/485) tunnel. UDP_IP Description: end IP address where MTX-Tunnel will send data to in UDP protocol. MTX-Tunnel needs be set in UDP mode (MTX_mode: udp). Possible values: IP address format XXX.XXX.XXX.XXX. DNS text string […]
Tunnel – TCP Configuration parameters: “TCP_”
This important configuration parameter relates to TCP protocol communication in MTX-Tunnel. They are mandatory when using 2G/3G/4G TCP – Serial RS232/485 tunnel in client (MTX_mode: client) or server mode (MTX_mode: server) TCP_IP Description: IP server address that MTX-Tunnel will connect to if it is client configured (MTX_mode: client). Possible values: IP address format XXX.XXX.XXX.XXX or DNS […]
Tunnel – GPRS connection configuration parameters: “GPRS_”
The following parameters are mandatory. They make reference to the MTX-Tunnel connection parameters related to the network operator. It depends on the SIM card and provisioned 2G/3G/4G service. Ask your network operator for further information. GPRS_apn, GPRS_apn2 Description: 2G/3G/4G Access Point Name -APN- Possible values: <100 characters text string Default value: movistar.es Additional notes: Some […]
Tunnel – Wakeup Configuration Parameter: “WAKEUP_”
The previous MTX-Tunnel V5 version could only be used for GPRS-serial tunnel Gateway in the following ways: 100% active after modem power-up X minutes active upon demand, after receiving an SMS with special text string “mtxtunnel on” or when receiving a missed call from an authorized configured phone number From version 5.0 more features have been added […]
Tunnel – WebServer Configuration Parameters: “WEBSERVER_”
WebServer configuration parameter starts with “WEBSERVER_”. MTX-Tunnel features a small WebServer which you can easily access with Internet Explorer software and check any modem’s state, network information, input state, or you could change a digital output, etc. WEBSERVER_enabled Description: specifies if the MTX-Tunnel webserver should be activated or not. Through the webserver you can visualized easily the […]
Tunnel – Telnet Configuration Parameters: “TELNET_”
Telnet configuration parameters start with a “TELNET” prefix. Telnet is recommended to remotely send AT commands, to change some configuration parameters or to find out the status of the remote modem with MTX-Tunnel. It is important to understand that Telnet will only work if the GPRS link has been established previously. You can see TELNET […]

Geben Sie den Verbindungsmodus „ethernet“ oder „modem“ ein:
Stellen Sie bei einer Ethernet-Konfiguration sicher, dass die IP-Parameter mit dem Serverzugriff entsprechend der lokalen Netzwerkkonfiguration des Hubs kompatibel sind. Bei einer Ethernet-Verbindung muss die Konfiguration mit der lokalen Netztopologie des Hubs kompatibel sein, damit dieser auf die Server zugreifen kann. Diese Konfiguration erfolgt über die Konfigurationsseite „Networks“ (siehe Kapitel 3.2.2.3: „Netzwerke (Networks)“).
Bei einer Modemverbindung muss das Modem korrekt konfiguriert sein, bevor eine Verbindung hergestellt werden kann. Diese Konfiguration erfolgt auf der Konfigurationsseite „Modem“ (siehe Kapitel 3.2.2.4: „Modem“).
Die minimal zu konfigurierenden Serverparameter sind folgende:
Diese Felder müssen konfiguriert werden: „Interface“, „Type“, „Server type“, „Address“, „Port“, „Login“ und „Password“.
In den übrigen Feldern können die Standardwerte beibehalten werden, solange die Verzeichnisse zuvor korrekt angelegt wurden. Weitere Einzelheiten siehe Kapitel 3.1.2: „Konfigurationsdateien“.

Warten Sie. Der Hub startet nach ein paar Augenblicken mit der Werkseinstellung neu.